Everpace RF
EverPace RF portfolio is designed for the diagnosis and treatment of cardiac arrhythmias through catheter-based electrophysiology procedures. The range includes the OptimAblate RF Generator, FireMagic RF Ablation Catheters and irrigated and 3D magnetic-navigation ablation catheters. These devices deliver controlled RF energy to create precise cardiac lesions that interrupt abnormal electrical pathways, while integrated temperature monitoring, irrigation, and advanced catheter steering help improve procedural accuracy and safety. The platform supports both conventional and complex ablation procedures, including atrial fibrillation and other tachyarrhythmias, and has received regulatory approvals in multiple international markets.
FireMagic Cardiac RF Ablation Catheter
The FireMagic Cardiac RF Ablation Catheter is a flexible and insulative catheter with a deflectable tip comprised of thermoplastic elastomer and several platinum electrodes, and in the tip a thermocouple temperature sensor is embedded. All of the electrodes may be used for cardiac mapping and stimulation purposes. For ablation, this catheter is used in conjunction with a RF generator and a dispersive electrode (reference electrode), and the large tip electrode delivers radio frequency current from the radio frequency lesion generator to the desired ablation site.

FireMagic TrueForce Ablation Catheter
FireMagic TrueForce Ablation Catheter is a multi-electrode luminal catheter with a deflectable tip designed to facilitate electrophysiological mapping of the heart and to transmit radio frequency (RF) current to the catheter tip electrode for ablation purposes. The diameter of the catheter shaft is 8F. For ablation, the catheter is used in conjunction with an RF generator and a dispersive pad.

FORLNK Cable for Ablation Catheter
The cable is designed to connect a Cardiac Radiofrequency (RF) Ablation Catheter to the appropriate RF generator. The cable may also be reused subjected to the reuse instructions provided below.

OptimAblate Cardiac RF Generator
OptimAblate Cardiac RF Generator is a device intended for RF ablation therapy of the human heart. It generates RF energy and continuously coordinates RF energy output, the temperature of the catheter’s tip electrode, and the tissue impedance during ablation therapy. When the RF energy heats the tissue, unwanted electrical pathways are interrupted or destroyed, thereby normal heart function restores.

OptimAblate™ Irrigation Pump
OptimAblate Irrigation Pump is a peristaltic pump designed to work with the OptimAblate RF Generator to deliver irrigation solution at specified flow rates to irrigated catheters for cooling purpose. The feature of double bubble detection of the pump ensures the safety and reliability of operations.

OptimAblate™ Tubing Set
The OptimAblate Tubing Set is a single-use accessory designed for use with the OptimAblate Irrigation Pump. When connected to a cardiac RF generator, the tubing set links an infusion bag or bottle to an irrigated ablation catheter. It enables precise, constant-flow delivery of room-temperature normal saline to the catheter tip. This controlled irrigation helps cool local tissue, reduce the risk of thrombosis, enhance ablation efficiency, and support improved procedural success rates.





